SAP® Documentation

Single view

CPA57AC - Controller &24 failed. No virtual circuits available. (C R) ( OS/400 )

Fill RESBD Structure from EBP Component Structure   General Data in Customer Master  
This documentation is copyright by IBM.
SAP E-Book


Message : CPA57AC
Controller &24 failed. No virtual circuits available. (C R)

Message Long Text :

Cause . . . . . : The system was not able to allocate a logical channel on line &23 to be used for controller &24. One of the following occurred:
-- The only available logical channel has been allocated for an incoming call.
-- The logical channel is in the process of recovering from a previous error.
Recovery . . . : Wait approximately 7 minutes for recovery to complete. Then try the request again.
If the problem continues, report the problem (ANZPRB command).
Possible choices for replying to message . . . . . . . . . . . . . . . :
C -- Cancel recovery and inform any applications that are waiting for an operation that the recovery has been canceled.
R -- Try the operation one more time.
Technical description . . . . . . . . : The error log identifier is &22.
The packet level was not able to make a connection because no outgoing or two-way virtual circuit was available. This may be due to an incoming call taking the last virtual circuit at the same time the local system is in the process of trying to call out.
The error code is &40. Error codes and their meanings follow:
32003172 -- Outgoing and two-way logical channel not available.
32004170 -- No available logical link.
32004172 -- No outgoing or two-way logical link available.

Message File : QCPFMSG
Library Message File : QSYS2924


Fill RESBD Structure from EBP Component Structure   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by IBM.

Length: 3265 Date: 20191121 Time: 125540     sap01-206 ( 1 ms )