SAP® Documentation

Single view

/BEV1/EMC734 - Movement type & for tied empty is incorrect - /BEV1/EMC 734

rdisp/max_wprun_time - Maximum work process run time   ROGBILLS - Synchronize billing plans  
This documentation is copyright by SAP AG.
SAP E-Book

Diagnosis

The table /bev1/emppbwart contains the movement types of the associated empties that were generated from the production order.

An incorrect entry was made in this table. There are several reasons for this:

1. The table is empty or contains empty fields.

2. At least one movement type was specified there that was not created.

3. Customizing for the movement type is incorrect or is not fully maintained.

System Response

Goods movements for the full product and the associated empties were not posted.

Procedure

Change the entry in table /bev1/emppbwart, or:

1./2. Create the required movement type.

3. Check and maintain Customizing for the movement type(s).

After this you can postprocess the incorrect goods movements. You can only post goods movements if both movement types from table /bev1/emppbwart are correctly maintained.

Procedure for System Administration






SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   PERFORM Short Reference  
This documentation is copyright by SAP AG.

Length: 1109 Date: 20191114 Time: 001227     sap01-206 ( 6 ms )